Skip to main content
TrueWattLab
Menu

Sump Pump Battery Backup Calculator

Direct Engineering Answer

Sump pumps are dictated by Locked Rotor Amps (LRA) startup surges, not average Watt-hours. While a 1/3 HP Wayne PSC pump starts near ~1,400 W, a cast-iron Zoeller M98 1/2 HP draws 1,080 W running and 29.2 A (~3,358 W) startup surge—requiring a >=3,400 W true inductive surge rating and disabling AC Auto-Shutoff.

1. Active Appliances & Duty Cycle

1 load active
Sump Pump 1/2 HP120V AC

Source: Zoeller M98 Official Electrical Datasheet (29.2 A LRA)

Quick Try:
Inspected Station TelemetryWarning

BLUETTI Elite 100 V2

1024 Wh · 1800 W
Estimated Runtime5.0 h
Total Avg Draw (+Idle)179.0 W162.0W load + 17.0W idle
Continuous AC1080 W
Sustained Peak1080 W
Inductive Surge3400 W
Inverter Continuous Load1080 / 1800 W (60%)
Inductive Surge 3400 / 3600 W (94%)
Tight surge headroom (6% remaining below 3600 W surge limit).
Verified Pure Sine Wave output required for motors, medical devices, or Active PFC PSUs.
Disable AC Eco Mode / Auto-Shutoff so the inverter stays awake between compressor or float-switch cycles.
Estimated runtime (5.0 h) is under your 24 h target without expansion or solar recharge.
Show Auditable Physics Breakdown
Wh_effective = 1024 Wh × 0.870 (eff) × 1.00 (temp) × 1.00 (res) = 890.9 Wh
Total_draw = 162.00 W (avg load) + 17.0 W (AC idle) = 179.00 W
Runtime = 890.9 / 179.00 = 5.0 h
Daily Gross Battery Energy: 4938 Wh/day

2. Top Recommended Matches for This Load

Selected deterministically from stations passing Level 1–3 electrical checks.

Best Budget Fit~$474

BLUETTI Elite 100 V2

1024 Wh · 1800W / 3600W surge · 25.3 lbs

Est. Runtime5.0 h
$0.53/useful Wh4,000 cyc @ ≥80%
Best Value ($/Useful Wh)~$999

Jackery Explorer 2000 v2

2042 Wh · 2200W / 4400W surge · 39.5 lbs

Est. Runtime9.6 h
$0.58/useful Wh4,000 cyc @ ≥70%
Best Solar & Heavy Surge~$3000

Anker SOLIX F3800 Plus

3840 Wh · 6000W / 9000W surge · 135.6 lbs

Est. Runtime16.5 h
$0.95/useful Wh3,000 cyc @ ≥80%

3. Full 20-Model Compatibility Table

Click any row to inspect its exact electrical breakdown and solar metrics in Telemetry above.

Model & SpecStatusEst. RuntimeAC / Inductive SurgeCycles / SolarStreet $/Useful WhCheck Price
1024 Wh · 25.3 lbs
warning5.0 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.53/Wh
$449–$499
1024 Wh · 27.6 lbs
warning5.0 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.77/Wh
$669–$719
2042 Wh · 39.5 lbs
warning9.6 h
2200 W cont.
4400 W surge
4,000 @ ≥70%
400 W solar
$0.58/Wh
$999
EcoFlow DELTA 2 Max
2048 Wh · 50.7 lbs
warning9.9 h
2400 W cont.
4800 W surge
3,000 @ ≥80%
1000 W solar
$0.63/Wh
$1029–$1299
Anker SOLIX C2000 Gen 2
2048 Wh · 41.7 lbs
warning9.7 h
2400 W cont.
4000 W surge
4,000 @ ≥80%
800 W solar
$0.80/Wh
$1300–$1500
2048 Wh · 48.7 lbs
warning9.1 h
3000 W cont.
6000 W surge
4,000 @ ≥80%
1000 W solar
$0.86/Wh
$1399–$1599
BLUETTI Apex 300
2764.8 Wh · 83.78 lbs
warning13.2 h
3840 W cont.
7680 W surge
6,000 @ ≥80%
2400 W solar
$0.72/Wh
$1699–$1800
Jackery Explorer 2000 Plus
2042.8 Wh · 61.5 lbs
warning8.8 h
3000 W cont.
6000 W surge
4,000 @ ≥70%
1400 W solar
$1.06/Wh
$1569–$1999
Jackery Explorer 3000 v2
3072 Wh · 59.5 lbs
warning13.6 h
3600 W cont.
7200 W surge
4,000 @ ≥70%
1000 W solar
$0.96/Wh
$2499
3840 Wh · 135.6 lbs
warning16.5 h
6000 W cont.
9000 W surge
3,000 @ ≥80%
3200 W solar
$0.95/Wh
$2999.99
4096 Wh · 113.54 lbs
warning18.8 h
4000 W cont.
8000 W surge
4,000 @ ≥80%
2600 W solar
$0.82/Wh
$2799–$3299
Anker SOLIX C300 (AC)
288 Wh · 9.1 lbs
Fail L1

Continuous load (1080 W) exceeds Anker SOLIX C300 (AC)'s 300 W continuous AC rating.

1.4 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.81/Wh
$190–$210
Jackery Explorer 300 Plus
288 Wh · 8.27 lbs
Fail L1

Continuous load (1080 W) exceeds Jackery Explorer 300 Plus's 300 W continuous AC rating.

1.4 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.92/Wh
$200–$250
286 Wh · 10.4 lbs
Fail L1

Continuous load (1080 W) exceeds EcoFlow RIVER 3 Plus's 600 W continuous AC rating.

1.5 h
600 W cont.
1200 W surge
3,000 @ ≥80%
220 W solar
$1.23/Wh
$299
BLUETTI AC50B
448 Wh · 14.8 lbs
Fail L1

Continuous load (1080 W) exceeds BLUETTI AC50B's 700 W continuous AC rating.

2.4 h
700 W cont.
N/V (Power Lifting 1000W)
3,000 @ ≥80%
200 W solar
$0.84/Wh
$279–$399
BLUETTI AC180
1152 Wh · 35.3 lbs
Fail L3

Inductive surge (3400 W) exceeds continuous 1800 W and BLUETTI AC180 does not publish a separate verified inductive surge rating (Power Lifting is resistive-only).

5.4 h
1800 W cont.
N/V (Power Lifting 2700W)
3,500 @ ≥80%
500 W solar
$0.51/Wh
$449–$549
1024 Wh · 24.9 lbs
Fail L3

Coincident inductive surge (3400 W) exceeds Anker SOLIX C1000 Gen 2's 3000 W surge rating.

5.2 h
2000 W cont.
3000 W surge
4,000 @ ≥80%
600 W solar
$0.56/Wh
$470–$530
1070 Wh · 23.8 lbs
Fail L3

Coincident inductive surge (3400 W) exceeds Jackery Explorer 1000 v2's 3000 W surge rating.

5.1 h
1500 W cont.
3000 W surge
4,000 @ ≥70%
400 W solar
$0.60/Wh
$499–$599
2073.6 Wh · 53.4 lbs
Fail L3

Inductive surge (3400 W) exceeds continuous 2600 W and BLUETTI Elite 200 V2 does not publish a separate verified inductive surge rating (Power Lifting is resistive-only).

11.0 h
2600 W cont.
N/V (Power Lifting 3900W)
6,000 @ ≥80%
1000 W solar
$0.47/Wh
$799–$999
Anker SOLIX F2600
2560 Wh · 69.7 lbs
Fail L3

Coincident inductive surge (3400 W) exceeds Anker SOLIX F2600's 2800 W surge rating.

12.1 h
2400 W cont.
2800 W surge
3,000 @ ≥80%
1000 W solar
$0.80/Wh
$1499–$1999

Key Engineering Takeaways

  • Motor topology matters: PSC pumps (Wayne) have ~1,400-2,200 W surges, while split-phase cast-iron pumps (Zoeller M53/M98) surge up to 2,875-3,358 W.
  • Never rely on resistive Power Lifting / X-Boost ratings to start a submersible sump pump motor—always match against true inductive surge specs.
  • A 24/7 AC inverter waiting on a float switch burns 15-40 W idle continuously; disable Eco Mode / Auto-Shutoff or your basement will flood between cycles.
Verified Technical Sources: Zoeller Pump Company M53 & M98 Electrical Specifications · Wayne Water Systems CDU790 / CDU800 Engineering Datasheets

Frequently Asked Questions

Will a 1,800W power station run a 1/2 HP sump pump?+
Only if its true inductive surge rating clears your pump's LRA spike. A Zoeller M98 (29.2 A / ~3,358 W LRA) will overload stations with <3,400 W surge (like 2,800 W surge models) or unverified Power Lifting ratings.
Why does my sump pump kill the battery even when it barely runs?+
Waiting 24 hours on a float switch requires leaving the AC inverter powered continuously, consuming ~360-850 Wh/day in idle overhead on top of active pumping cycles.
What happens if AC Eco Mode is left turned on?+
The power station detects 0 W while the float switch is down, automatically shuts off AC output after 15-60 minutes, and leaves the pump unpowered when water rises.

More TrueWattLab Sizing Calculators