Skip to main content
TrueWattLab
Menu
Specs & Load Profiles Verified: 2026-11-22

Physics-Based Portable Power Station & Backup Sizing Calculator

Stop guessing with naive Wh / W math. Model real inverter efficiency, AC idle draw, EnergyGuide kWh/year labels, and 3-level inductive motor surges across 20 verified 2025–2026 power stations.

1. Active Appliances & Duty Cycle

2 loads active
Modern Refrigerator120V AC

Source: U.S. DOE / ENERGY STAR Flip Your Fridge & EnergyGuide

Wi-Fi Router + Modem120V AC

Source: EPA ENERGY STAR Small Network Equipment & NRDC Studies

DC Tip: Most routers and ONTs take 12 V DC barrel input; a USB-C PD 12V trigger cable eliminates AC inverter idle waste.

Quick Try:
Inspected Station TelemetryCompatible

BLUETTI Elite 200 V2

2073.6 Wh · 2600 W
Estimated Runtime24.1 h
Total Avg Draw (+Idle)79.0 W67.5W load + 11.5W idle
Continuous AC165 W
Sustained Peak165 W
Inductive Surge1215 W
Inverter Continuous Load165 / 2600 W (6%)
Inductive Surge (N/V cap)1215 / 2600 W (47%)
Solar Needed (4.2 PSH)629 W array

Daily gross load: 2061 Wh/day. Fits within BLUETTI Elite 200 V2's 1000 W solar cap.

BLUETTI Elite 200 V2 does not publish a separate inductive surge spec outside Power Lifting.
Verified Pure Sine Wave output required for motors, medical devices, or Active PFC PSUs.
Verify manufacturer EPS/UPS switchover time (<=10-20 ms) before relying on unattended pass-through.
Disable AC Eco Mode / Auto-Shutoff so the inverter stays awake between compressor or float-switch cycles.
Show Auditable Physics Breakdown
Wh_effective = 2073.6 Wh × 0.920 (eff) × 1.00 (temp) × 1.00 (res) = 1907.7 Wh
Total_draw = 67.50 W (avg load) + 11.5 W (AC idle) = 79.00 W
Runtime = 1907.7 / 79.00 = 24.1 h
Daily Gross Battery Energy: 2061 Wh/day

2. Top Recommended Matches for This Load

Selected deterministically from stations passing Level 1–3 electrical checks.

Best Budget Fit~$899

BLUETTI Elite 200 V2

2073.6 Wh · 2600W / N/VW surge · 53.4 lbs

Est. Runtime24.1 h
$0.47/useful Wh6,000 cyc @ ≥80%
Best Value ($/Useful Wh)~$1750

BLUETTI Apex 300

2764.8 Wh · 3840W / 7680W surge · 83.78 lbs

Est. Runtime27.0 h
$0.72/useful Wh6,000 cyc @ ≥80%
Best Solar & Heavy Surge~$3000

Anker SOLIX F3800 Plus

3840 Wh · 6000W / 9000W surge · 135.6 lbs

Est. Runtime32.5 h
$0.95/useful Wh3,000 cyc @ ≥80%

3. Full 20-Model Compatibility Table

Click any row to inspect its exact electrical breakdown and solar metrics in Telemetry above.

Model & SpecStatusEst. RuntimeAC / Inductive SurgeCycles / SolarStreet $/Useful WhCheck Price
2073.6 Wh · 53.4 lbs
pass24.1 h
2600 W cont.
N/V (Power Lifting 3900W)
6,000 @ ≥80%
1000 W solar
$0.47/Wh
$799–$999
Anker SOLIX F2600
2560 Wh · 69.7 lbs
pass25.5 h
2400 W cont.
2800 W surge
3,000 @ ≥80%
1000 W solar
$0.80/Wh
$1499–$1999
BLUETTI Apex 300
2764.8 Wh · 83.78 lbs
pass27.0 h
3840 W cont.
7680 W surge
6,000 @ ≥80%
2400 W solar
$0.72/Wh
$1699–$1800
Jackery Explorer 3000 v2
3072 Wh · 59.5 lbs
pass26.8 h
3600 W cont.
7200 W surge
4,000 @ ≥70%
1000 W solar
$0.96/Wh
$2499
3840 Wh · 135.6 lbs
pass32.5 h
6000 W cont.
9000 W surge
3,000 @ ≥80%
3200 W solar
$0.95/Wh
$2999.99
4096 Wh · 113.54 lbs
pass36.2 h
4000 W cont.
8000 W surge
4,000 @ ≥80%
2600 W solar
$0.82/Wh
$2799–$3299
1024 Wh · 25.3 lbs
warning10.5 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.53/Wh
$449–$499
BLUETTI AC180
1152 Wh · 35.3 lbs
warning11.5 h
1800 W cont.
N/V (Power Lifting 2700W)
3,500 @ ≥80%
500 W solar
$0.51/Wh
$449–$549
1024 Wh · 24.9 lbs
warning11.6 h
2000 W cont.
3000 W surge
4,000 @ ≥80%
600 W solar
$0.56/Wh
$470–$530
1070 Wh · 23.8 lbs
warning10.6 h
1500 W cont.
3000 W surge
4,000 @ ≥70%
400 W solar
$0.60/Wh
$499–$599
1024 Wh · 27.6 lbs
warning10.7 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.77/Wh
$669–$719
2042 Wh · 39.5 lbs
warning20.2 h
2200 W cont.
4400 W surge
4,000 @ ≥70%
400 W solar
$0.58/Wh
$999
EcoFlow DELTA 2 Max
2048 Wh · 50.7 lbs
warning19.9 h
2400 W cont.
4800 W surge
3,000 @ ≥80%
1000 W solar
$0.63/Wh
$1029–$1299
Anker SOLIX C2000 Gen 2
2048 Wh · 41.7 lbs
warning20.4 h
2400 W cont.
4000 W surge
4,000 @ ≥80%
800 W solar
$0.80/Wh
$1300–$1500
2048 Wh · 48.7 lbs
warning17.9 h
3000 W cont.
6000 W surge
4,000 @ ≥80%
1000 W solar
$0.86/Wh
$1399–$1599
Jackery Explorer 2000 Plus
2042.8 Wh · 61.5 lbs
warning17.3 h
3000 W cont.
6000 W surge
4,000 @ ≥70%
1400 W solar
$1.06/Wh
$1569–$1999
Anker SOLIX C300 (AC)
288 Wh · 9.1 lbs
Fail L3

Coincident inductive surge (1215 W) exceeds Anker SOLIX C300 (AC)'s 600 W surge rating.

3.3 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.81/Wh
$190–$210
Jackery Explorer 300 Plus
288 Wh · 8.27 lbs
Fail L3

Coincident inductive surge (1215 W) exceeds Jackery Explorer 300 Plus's 600 W surge rating.

3.2 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.92/Wh
$200–$250
286 Wh · 10.4 lbs
Fail L3

Coincident inductive surge (1215 W) exceeds EcoFlow RIVER 3 Plus's 1200 W surge rating.

3.3 h
600 W cont.
1200 W surge
3,000 @ ≥80%
220 W solar
$1.23/Wh
$299
BLUETTI AC50B
448 Wh · 14.8 lbs
Fail L3

Inductive surge (1215 W) exceeds continuous 700 W and BLUETTI AC50B does not publish a separate verified inductive surge rating (Power Lifting is resistive-only).

5.4 h
700 W cont.
N/V (Power Lifting 1000W)
3,000 @ ≥80%
200 W solar
$0.84/Wh
$279–$399

Outage, RV & Solar Scenario Builders

Pre-configured multi-appliance and off-grid solar sizing utilities.

Browse Full 20-Model Spec Database →

Appliance-Specific Backup Calculators (15 Tools)

Dedicated calculators pre-loaded with official DOE, ENERGY STAR, ResMed, Zoeller, Starlink, and Dometic power specs.

CPAP Battery Backup Runtime Calculator

Calculate real CPAP battery runtime with and without heated humidifiers, compare 12V/24V DC vs. AC inverter idle drain, and find compatible LFP units.

Open calculator →

Refrigerator Power Station Runtime Calculator

Calculate how long a portable power station runs a full-size refrigerator using EnergyGuide kWh/year, real compressor duty cycles, and 1,200-1,800 W surge checks.

Open calculator →

Chest Freezer Battery Backup Runtime Calculator

Estimate how long a portable power station runs a 5-7 cu ft chest freezer using real 30% duty cycles, 600 W surge requirements, and AC idle loss.

Open calculator →

Sump Pump Battery Backup Calculator

Size a portable power station for a 1/3 HP or 1/2 HP sump pump using real Locked Rotor Amps (Zoeller M98 3,358 W vs. Wayne PSC) and storm duty cycles.

Open calculator →

Starlink Portable Power Station Runtime Calculator

Calculate Starlink Gen 3 (75-100 W) and Starlink Mini (25-40 W DC) battery runtime with Snow Melt toggles and AC vs. DC power supply comparison.

Open calculator →

Wi-Fi Router & Modem Battery Backup Calculator

Find out how long a power station runs your Wi-Fi router and modem—and why AC inverter idle draw cuts runtime in half vs. a 12V DC cable.

Open calculator →

Home Office Power Outage Runtime Calculator

Calculate battery backup runtime for working from home: laptop, 27-inch monitor, LED desk light, and Wi-Fi router across 8-hour workdays.

Open calculator →

12V Portable Camper Fridge Runtime Calculator

Calculate how many days a portable power station runs a 12V compressor fridge (45-55L) at 25% vs. hot van 50% duty cycles and size off-grid solar panels.

Open calculator →

Space Heater Portable Power Station Runtime Calculator

See exact minutes and hours an electric space heater (750 W Low / 1,500 W High) runs on 1 kWh-4 kWh portable batteries—and why electric heat drains packs fast.

Open calculator →

Microwave Portable Power Station Calculator

Convert microwave cooking watts (700 W, 1,000 W, 1,100 W) into actual AC wall draw (~1,150-1,650 W) so you never overload your power station inverter.

Open calculator →

Coffee Maker & Keurig Power Station Calculator

Compare drip coffee makers (1,000 W) vs. Keurig single-serve brewers (1,500 W) on portable power stations: watts needed, Wh per cup, and compatible models.

Open calculator →

Window AC Portable Power Station Runtime Calculator

Compare standard 5,000/8,000 BTU window ACs (1,500-2,200 W surge) vs. 8,000 BTU Inverter units like Midea U (<800 W soft-start) on portable power stations.

Open calculator →

Pellet Stove Battery Backup Runtime Calculator

Size a pure sine wave power station for a Harman or PelPro pellet stove: models the 450 W 4-8 minute igniter spike separately from 100 W steady blower load.

Open calculator →

Oxygen Concentrator Battery Backup Calculator

Calculate backup battery hours for 5L/10L stationary oxygen concentrators vs. portable POCs, with pure sine wave, surge, and critical medical safety checks.

Open calculator →

Gaming PC & Console Power Station Runtime Calculator

Estimate battery runtime for a mid-range gaming PC + 27" monitor (~400 W) or PS5/Xbox + 55" TV (~290 W), with Pure Sine Wave and <20 ms UPS checks.

Open calculator →

2026 Head-to-Head Tier Comparisons

Model-Specific Runtime & Spec Calculators

Engineering Methodology Guides

How to Calculate Real Power Station Runtime (Physics Formula & Inverter Losses)

Dividing rated Watt-hours by appliance Watts overestimates real battery runtime by 20%-55%. Accurate runtime equals (Capacity Wh x Conversion Efficiency x Temperature Factor) divided by (Average Appliance Watts + Continuous Inverter Idle Draw), avoiding double-counting losses while accounting for duty cycles and cold-weather battery derating.

Running Watts vs. Inductive Surge vs. Sustained Peaks Explained

Power station compatibility requires passing three distinct electrical tiers: simultaneous continuous load, sustained multi-minute peaks (like a 450 W pellet stove igniter for 6 minutes), and sub-second Locked Rotor Amps (LRA) motor surges (like 3,358 W on a Zoeller M98 1/2 HP sump pump). Resistive voltage-drop features (X-Boost, Power Lifting, SurgePad) do NOT provide inductive motor startup current.

AC vs. DC Inverter Idle Draw: Double Runtime on Small Loads

Keeping an AC inverter powered draws 4 W to 40 W continuously even when your plugged-in load is tiny or asleep. Running a 12 W CPAP or 15 W Wi-Fi router on 12V/USB-C DC instead of AC doubles or triples real runtime (e.g., 78.5 h vs. 31.1 h on 1,024 Wh). Meanwhile, leaving AC Auto-Shutoff enabled can fatally shut off power between fridge or sump pump cycles.

LiFePO4 Cycle Life Explained: The 80% vs. 70% Spec Trap

Virtually all 2025-2026 flagship stations use LiFePO4 (LFP) chemistry, delivering 6-15x longer lifespan than older NMC lithium packs. However, cycle ratings are not standardized: EcoFlow, BLUETTI, and Anker rate cycles down to >=80% remaining capacity, whereas Jackery v2 and Plus models rate 4,000 cycles down to >=70% retention.

Frequently Asked Questions

Why does TrueWattLab calculate shorter runtime than simple Wh / Watts calculators?+
Simple Wh / Watts math ignores AC inverter conversion losses (~10%-18%), continuous inverter idle draw (4-40 W just to keep 120V circuits awake), and appliance compressor duty cycles. Our engine models all three explicitly without double-counting BMS reserves.
Why can Power Lifting or X-Boost fail on sump pumps and refrigerators?+
Features like X-Boost, Power Lifting, and SurgePad lower output voltage to run high-wattage resistive heaters (hair dryers, kettles). Electric motors and compressor pumps require full voltage and high Locked Rotor Amps (LRA) inductive surge—so our matcher never assumes resistive boost covers motors.
Which power station battery cycle ratings are measured to 80% vs. 70%?+
EcoFlow, BLUETTI, and Anker SOLIX rate their LiFePO4 cycles until 80% capacity retention, whereas Jackery Explorer 1000 v2, 2000 v2, and 3000 v2 specify 4,000 cycles down to >=70% retention. TrueWattLab displays both thresholds transparently.