Skip to main content
TrueWattLab
Menu

RV & Campervan Off-Grid Power Station Calculator

Direct Engineering Answer

An all-DC vanlife setup (12V compressor fridge ~12.5 Wh/h + Starlink Mini 30 W + USB-C laptop work 8h/day) consumes ~1,260 Wh/day at 0 W AC inverter idle waste. A 1,024-2,048 Wh station paired with 400-600 W of rooftop solar runs indefinitely across sunny 4.8-PSH climates.

1. Active Appliances & Duty Cycle

3 loads active
12V Camper FridgeDC / USB-C

Source: Dometic CFX3 45 / 55 Official Technical Specs

DC Tip: Connect via regulated 12 V DC socket (>=10 A rated) to prevent AC inverter idle losses.

Starlink Mini (DC)DC / USB-C

Source: Starlink Mini Official Specifications

DC Tip: Native 12-48 V DC barrel or USB-C PD (>=100 W / 20V 5A port required).

Home Office Setup120V AC

Source: U.S. DOE & ENERGY STAR Computer/Display Benchmarks

DC Tip: Powering the laptop and desk lamp via USB-C DC while keeping monitor usage minimal extends 8-hour workday runtime.

Quick Try:
Inspected Station TelemetryCompatible

EcoFlow DELTA Pro 3

4096 Wh · 4000 W
Estimated Runtime26.0 h
Total Avg Draw (+Idle)142.5 W107.5W load + 35.0W idle
Continuous AC65 W
Sustained Peak65 W
Inductive Surge65 W
Inverter Continuous Load65 / 4000 W (2%)
Inductive Surge 65 / 8000 W (1%)
Solar Needed (4.8 PSH)537 W array

Daily gross load: 2011 Wh/day. Fits within EcoFlow DELTA Pro 3's 2600 W solar cap.

AC vs. DC Advantage: 1.35x Longer via DC

Running your DC-capable load directly via 12V/USB-C yields 35.1 h vs. 26.0 h on AC (gaining +9.0 h by eliminating inverter idle waste).

Verified Pure Sine Wave output required for motors, medical devices, or Active PFC PSUs.
Verify manufacturer EPS/UPS switchover time (<=10-20 ms) before relying on unattended pass-through.
Disable AC Eco Mode / Auto-Shutoff so the inverter stays awake between compressor or float-switch cycles.
Show Auditable Physics Breakdown
Wh_effective = 4096 Wh × 0.905 (eff) × 1.00 (temp) × 1.00 (res) = 3706.9 Wh
Total_draw = 107.50 W (avg load) + 35.0 W (AC idle) = 142.50 W
Runtime = 3706.9 / 142.50 = 26.0 h
Daily Gross Battery Energy: 2011 Wh/day

2. Top Recommended Matches for This Load

Selected deterministically from stations passing Level 1–3 electrical checks.

Best Budget Fit~$3049

EcoFlow DELTA Pro 3

4096 Wh · 4000W / 8000W surge · 113.54 lbs

Est. Runtime26.0 h
$0.82/useful Wh4,000 cyc @ ≥80%

3. Full 20-Model Compatibility Table

Click any row to inspect its exact electrical breakdown and solar metrics in Telemetry above.

Model & SpecStatusEst. RuntimeAC / Inductive SurgeCycles / SolarStreet $/Useful WhCheck Price
4096 Wh · 113.54 lbs
pass26.0 h
4000 W cont.
8000 W surge
4,000 @ ≥80%
2600 W solar
$0.82/Wh
$2799–$3299
Anker SOLIX C300 (AC)
288 Wh · 9.1 lbs
warning2.1 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.81/Wh
$190–$210
Jackery Explorer 300 Plus
288 Wh · 8.27 lbs
warning2.1 h
300 W cont.
600 W surge
3,000 @ ≥80%
100 W solar
$0.92/Wh
$200–$250
286 Wh · 10.4 lbs
warning2.2 h
600 W cont.
1200 W surge
3,000 @ ≥80%
220 W solar
$1.23/Wh
$299
BLUETTI AC50B
448 Wh · 14.8 lbs
warning3.5 h
700 W cont.
N/V (Power Lifting 1000W)
3,000 @ ≥80%
200 W solar
$0.84/Wh
$279–$399
1024 Wh · 25.3 lbs
warning7.2 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.53/Wh
$449–$499
BLUETTI AC180
1152 Wh · 35.3 lbs
warning7.8 h
1800 W cont.
N/V (Power Lifting 2700W)
3,500 @ ≥80%
500 W solar
$0.51/Wh
$449–$549
1024 Wh · 24.9 lbs
warning7.7 h
2000 W cont.
3000 W surge
4,000 @ ≥80%
600 W solar
$0.56/Wh
$470–$530
1070 Wh · 23.8 lbs
warning7.2 h
1500 W cont.
3000 W surge
4,000 @ ≥70%
400 W solar
$0.60/Wh
$499–$599
1024 Wh · 27.6 lbs
warning7.2 h
1800 W cont.
3600 W surge
4,000 @ ≥80%
1000 W solar
$0.77/Wh
$669–$719
2073.6 Wh · 53.4 lbs
warning16.0 h
2600 W cont.
N/V (Power Lifting 3900W)
6,000 @ ≥80%
1000 W solar
$0.47/Wh
$799–$999
2042 Wh · 39.5 lbs
warning13.7 h
2200 W cont.
4400 W surge
4,000 @ ≥70%
400 W solar
$0.58/Wh
$999
EcoFlow DELTA 2 Max
2048 Wh · 50.7 lbs
warning13.9 h
2400 W cont.
4800 W surge
3,000 @ ≥80%
1000 W solar
$0.63/Wh
$1029–$1299
Anker SOLIX C2000 Gen 2
2048 Wh · 41.7 lbs
warning13.9 h
2400 W cont.
4000 W surge
4,000 @ ≥80%
800 W solar
$0.80/Wh
$1300–$1500
2048 Wh · 48.7 lbs
warning12.7 h
3000 W cont.
6000 W surge
4,000 @ ≥80%
1000 W solar
$0.86/Wh
$1399–$1599
Anker SOLIX F2600
2560 Wh · 69.7 lbs
warning17.3 h
2400 W cont.
2800 W surge
3,000 @ ≥80%
1000 W solar
$0.80/Wh
$1499–$1999
BLUETTI Apex 300
2764.8 Wh · 83.78 lbs
warning18.7 h
3840 W cont.
7680 W surge
6,000 @ ≥80%
2400 W solar
$0.72/Wh
$1699–$1800
Jackery Explorer 2000 Plus
2042.8 Wh · 61.5 lbs
warning12.3 h
3000 W cont.
6000 W surge
4,000 @ ≥70%
1400 W solar
$1.06/Wh
$1569–$1999
Jackery Explorer 3000 v2
3072 Wh · 59.5 lbs
warning19.0 h
3600 W cont.
7200 W surge
4,000 @ ≥70%
1000 W solar
$0.96/Wh
$2499
3840 Wh · 135.6 lbs
warning23.0 h
6000 W cont.
9000 W surge
3,000 @ ≥80%
3200 W solar
$0.95/Wh
$2999.99

Key Engineering Takeaways

  • Going 100% DC (12V Dometic-class fridge + Starlink Mini USB-C/DC + USB-C laptop charging) eliminates 250-500 Wh/day of wasted AC inverter idle draw.
  • Adding even short bursts of high-AC appliances (1,500 W microwave or Keurig) immediately dictates >=1,800 W continuous inverter ratings even if daily Wh is modest.
  • Hot summer camper vans (>95 F) double 12V fridge compressor duty cycles from 25% (~300 Wh/day) up to 50%+ (~600 Wh/day).
Verified Technical Sources: Dometic CFX3 Official Power Specs & Starlink Mini DC Specifications · NREL PVWatts Solar Irradiance Reference

Frequently Asked Questions

What size power station is best for a campervan with a 12V fridge and Starlink?+
A 1,024 Wh unit (like EcoFlow DELTA 3 Plus, BLUETTI Elite 100 V2, or Anker C1000 Gen 2) covers a full day comfortably when paired with 400 W+ solar, while 2,048 Wh gives a safe 2-day overcast buffer.
Should I run Starlink Standard Gen 3 or Mini in a campervan?+
Starlink Mini (~30 W native DC) uses less than one-third the battery of Starlink Standard Gen 3 (~85 W + AC inverter overhead), saving >1,400 Wh per 24 hours.
Can a 1,000Wh station run a rooftop or window RV AC?+
No. Even efficient 8,000 BTU inverter units draw ~350-710 W continuously, emptying 1,024 Wh in 1.5-2.5 hours. Off-grid AC requires 3-5+ kWh of battery capacity plus alternator/large solar charging.

More TrueWattLab Sizing Calculators